Home > Frx Error > Frx Error 9 Subscript Out Of Range Frl_entity

Frx Error 9 Subscript Out Of Range Frl_entity

The first thing that should happen is FRx recreates the GL index. Our COA is 3-5-4-4 But there were segment 1 values with a length of 6 in there as an example. By Athlonanime in forum Applications and Operating Systems Replies: 3 Last Post: March 26th, 2004, 08:09 PM Great Plains and FRX By iamsmiling in forum General Tech Discussion Replies: 0 Last there can be an error 91, an Error 9, or a more specific error message. Check This Out

Somehow the guy that loaded the initial COA messed it up several time and probably SQL deleted. Verify and try again. 91 - object variable or with block variable not set 3704 - operation is not allowed when the object is closed. I also have reports that export with formulas with same footer values. You may have an inconsistency between some of your gl tables in Dynamics, or some sort of permissions errors on the system.

Originally, I had installed withSP11, but removed it all and reinstalled just the base FRx 6.7 for SL7.0.Any ideas or help?Stuart Nottingham. Hillyer Website My Badges Francisco G. You will likely need assistance in getting a SQL Profile to determine the cause of the error. Let us know Reply Ann B My Badges Suggested Answer Ann B responded on 12 Feb 2013 11:16 AM I have had this happen about 3 times...always same issue.

This error can occur from a damaged .G32 file in the shared SysData directory, an inconsistency in the sy00300 and gl40200 tables, a permission error in Dynamics, or other potential issues. Thanks Ryan Reply Ann B My Badges Suggested Answer Ann B responded on 12 Feb 2013 11:16 AM I have had this happen about 3 times...always same issue. Reply FUNMILAYO My Badges FUNMILAYO responded on 8 Aug 2011 4:50 AM Hello, Thanks for your responce. Reply Francisco G.

In my case, this worked (set for 3-5-4-4). Please help me further. I am trying to understand if its a report writing or technical issue. http://reese-consulting.com/frx-launcher-run-time-error-9-subscript-out-of-range/ Ignore the warning - the report viewer will launch after the report is done.   Here are some more in-depth articles on error 9, mainly related to FRx Report Designer: http://support.microsoft.com/kb/865978

By Wombat in forum Networking and Internet Replies: 7 Last Post: April 4th, 2002, 01:11 PM Posting Permissions You may post new threads You may post replies You may not post Also I will suggest you review the SY01500 table and match agains the actual company databases you have, as you might have more companies on the table thatn the actual DB Thanks Ryan Reply Richard Wheeler Works For Revered Business Solutions, Inc. What changed since it lastworked (has the FRx version been recently upgraded)?I'd start by comparing the Company Information screens for the twocompanies.

If we uncheck that box, we do not get the error. https://community.dynamics.com/gp/f/32/t/60261 DELETE FROM GL40200 WHERE (SGMTNUMB = 1 AND LEN(SGMNTID) <> 3) OR (SGMTNUMB = 2 AND LEN(SGMNTID) <> 5) OR (SGMTNUMB = 3 AND LEN(SGMNTID) <> 4) OR (SGMTNUMB = 4 Do you know if any changes were recently made? in Ballston Lake, New York My Badges Richard Wheeler responded on 9 Aug 2011 7:29 AM I would try running check links on the financial series to see if it fixes

Stuart Nottingham 2010-02-24 10:15:24 UTC PermalinkRaw Message Nagesh, this turned out to be a discrepancy between the FlexDef andSegDef tables for the subaccount.Post by NageshHi Stuart,Did you ran the Frx Scripts?-NageshPost delete GL40200 where SGMTNUMB ='0' I ran checklinks in Financial after that to ensure the data was clean. microsoft.public.solomon Discussion: Error 9 Subscript out of range (too old to reply) Kambiz 2006-07-11 22:36:11 UTC PermalinkRaw Message I'm trying to set a default company. select * from GL40200 where SGMTNUMB ='0' then I deleted them.

in Kuwait LinkedIn My Badges Hossam Fathy responded on 25 Mar 2010 1:28 PM Try Compact FRx Database. Cloud Platform Stories Infrastructure Microsoft Azure Mobility Enterprise mobility Office mobility Windows mobility Microsoft Surface Microsoft Lumia Productivity Office Office 365 for business Plans and pricing Office 365 for SMB Office What can I do to fix the error? this contact form {{offlineMessage}} Try Microsoft Edge, a fast and secure browser that's designed for Windows 10 Get started Store Store home Devices Microsoft Surface PCs & tablets Xbox Virtual reality Accessories Windows phone

Reply Natarajan SankaraNarayanan Works For Business Experts Gulf in Dubai, U.A.E @natraj88 LinkedIn Google+ Blog Website My Badges Suggested Answer Natarajan SankaraNarayanan responded on 18 Aug 2014 1:19 AM Hi, Please delete GL40200 where SGMTNUMB ='0' I ran checklinks in Financial after that to ensure the data was clean. Notify me of new posts by email.

But i did what you asked me to do yet its not working.

If they are not in the samedatabase, you may need to run the FRx scripts for your FRx version againstthe second database.--Laura BarberPost by KambizI'm trying to set a default company. Any ideas?This sounds like the FRx scripts haven't been run in this database.Stuart Nottingham 2 Replies 53 Views Switch to linear view Disable enhanced parsing Permalink to this page Thread Navigation Thank you Reply JMcCoy JMcCoy responded on 8 Aug 2011 5:01 AM Here ya go: support.microsoft.com/.../964797 Reply FUNMILAYO My Badges FUNMILAYO responded on 9 Aug 2011 1:39 AM Thanks for your The error occured while populating the frl_entity table in the GLX database' 'FRx engine failed to create GL index file.' I've removed Sign In Share Twitter LinkedIn Facebook Email Print RSS

You could make this dynamic and pull from your setup if you wanted, I hard coded the lengths. Any ideas what could be causing this? Reply Reply With Quote April 6th, 2011,03:46 PM #4 Steve R Jones View Profile View Forum Posts View Blog Entries Ride 'em Cowboy Join Date Oct 2001 Location Dallas, TX navigate here If they are in the same database, the only difference wouldtypically be the code, name, and company id.

Please the server has enough space as regard the recomendation from support.microsoft.com/.../964797 . Thanks Sandip 210.440.9855 Reply Debbie O'Conner Debbie O'Conner responded on 26 Mar 2010 9:57 AM The headers and footers should both be reviewed. The GL40200 stores Segment Number, Value, Description (if you name them). What else can i do.

In all cases the segment master: gl40200, was imported and the header record was imported as well. Reply Industries Education Government Health Discrete Manufacturing Hospitality and travel Retail and consumer goods For customers Small and midsize businesses Enterprise Envision Microsoft Ignite Microsoft AppSource For partners Microsoft partner resources Thread Tools Show Printable Version Subscribe to this Thread… April 6th, 2011,09:01 AM #1 bj108 View Profile View Forum Posts View Blog Entries Junior Member Join Date Apr 2011 Posts So I deleted all the rows that had a SGMTNUMB > 4 But also noticed that there were funky values in there.

Any ideas? So: there is a segment ID of '0' that FRx has no idea what to do with. I've createdError 9Subscript out of range.(This error occurred while populating the frl_entity table in the GLXdatabase)FRx Engine Failed to create GL Index File.I've uninstalled and reinstalled. Not only did I find a record with the SGMTNUMB column with the value of '0', I found 12 records with values of '1100', '1200', etc.

Reply Birdwell Birdwell responded on 14 Aug 2014 4:50 PM I had the same issue with Sage MAS 500 version of FRx and found that either removing the export to Excel Thanks for sharing your experience. I've createdError 9Subscript out of range.(This error occurred while populating the frl_entity table in the GLXdatabase)FRx Engine Failed to create GL Index File.I've uninstalled and reinstalled. We only have 4 Segments, but there were 10 listed in this table.

Windows 2008 server. Reply Kevin Day My Badges Kevin Day responded on 18 Feb 2016 7:01 PM Just ran into this one as well and my solution was a bit different, but similar, so Determine this is your issue: select * from GL40200 where SGMTNUMB ='0' Run a delete statement like this: delete GL40200 where SGMTNUMB ='0' Reply Perry Smith - ISS Website My Badges So: there is a segment ID of '0' that FRx has no idea what to do with.

or check the user permission for appropriate company in GP? Hope this helps!!!